Nutrition
Volume 25, Issue 11 , Pages 1106-1114 , November 2009

Influence of different ventilator modes on Vo2 and Vco2 measurements using a compact metabolic monitor

  • George Briassoulis, M.D., Ph.D.

      Affiliations

    • Paediatric Intensive Care Unit, University Hospital of Heraklion, Heraklion, Crete, Greece
    • Corresponding Author InformationCorresponding author. Tel.: +2810-375024.
  • ,
  • Evi Michaeloudi, M.D.

      Affiliations

    • Paediatric Intensive Care Unit, University Hospital of Heraklion, Heraklion, Crete, Greece
  • ,
  • Diana-Michaela Fitrolaki, M.D.

      Affiliations

    • Paediatric Intensive Care Unit, University Hospital of Heraklion, Heraklion, Crete, Greece
  • ,
  • Anna-Maria Spanaki, M.D.

      Affiliations

    • Paediatric Intensive Care Unit, University Hospital of Heraklion, Heraklion, Crete, Greece
  • ,
  • Efrossini Briassouli, M.D.

      Affiliations

    • 1st Department of Internal Medicine–Propaedeutic, University of Athens, Athens, Greece

Received 21 October 2008 ,Accepted 31 January 2009.

References 

  1. Donaldson L, Dodds S, Walsh TS. Clinical evaluation of a continuous oxygen consumption monitor in mechanically ventilated patients. Anaesthesia. 2003;58:455–460
  2. Singer P, Pogrebetsky I, Attal-Singer J, Cohen J. Comparison of metabolic monitors in critically ill, ventilated patients. Nutrition. 2006;22:1077–1086
  3. McLellan S, Walsh T, Burdess A, Lee A. Comparison between the Datex-Ohmeda M-COVX metabolic monitor and the Deltatrac II in mechanically ventilated patients. Intensive Care Med. 2002;28:870–876
  4. Peerless JR, Epstein CD, Martin JE, Pinchak AC, Malangoni MA. Oxygen consumption in the early postinjury period: use of continuous, on-line indirect calorimetry. Crit Care Med. 2000;28:395–401
  5. Tisherman SA. Postinjury oxygen consumption: new method, no new answers. Crit Care Med. 2000;28:577–578
  6. Meyer R, Habibi P. Comparing methods for measuring energy expenditure in the critically ill. Nutrition. 2007;23:281
  7. El-Khatib M, Bou-Khalil P, Zeineldine S, Kanj N, Abi-Saad G, Jamaleddine G. Metabolic and respiratory variables during pressure support versus synchronized intermittent mandatory ventilation. Respiration. 2008;77(2):154–159
  8. Takala J, Meriläinen PT. Handbook of gas exchange and indirect calorimetry. Helsinki: Datex-Ohmeda; 2003;
  9. Branson RD, Johannigman JA. The measurement of energy expenditure. Nutr Clin Pract. 2004;19:622–636
  10. Pollack MM, Ruttimann UE, Getson PR. Pediatric risk of mortality (PRISM) score. Crit Care Med. 1988;16:1110–1116
  11. Keene AR, Cullen DJ. Therapeutic intervention scoring system: update 1983. Crit Care Med. 1983;11:1–3
  12. Oosterveld MJ, Van Der Kuip M, De Meer K, De Greef HJ, Gemke RJ. Energy expenditure and balance following pediatric intensive care unit admission: a longitudinal study of critically ill children. Pediatr Crit Care Med. 2006;7:147–153
  13. Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Method Med Res. 1999;8:135–160
  14. Epstein CD, Peerless JR, Martin JE, Malangoni MA. Comparison of methods of measurements of oxygen consumption in mechanically ventilated patients with multiple trauma: the Fick method versus indirect calorimetry. Crit Care Med. 2000;28:1363–1369
  15. Flancbaum L, Choban PS, Sambucco S, Verducci J, Burge JC. Comparison of indirect calorimetry, the Fick method, and prediction equations in estimating the energy requirements of critically ill patients. Am J Clin Nutr. 1999;69:461–466
  16. Hulst JM, Joosten KF, Tibboel D, van Goudoever JB. Causes and consequences of inadequate substrate supply to pediatric ICU patients. Curr Opin Clin Nutr Metab Care. 2006;9:297–303
  17. Miwa K, Mitsuoka M, Takamori S, Hayashi A, Shirouzu K. Continuous monitoring of oxygen consumption in patients undergoing weaning from mechanical ventilation. Respiration. 2003;70:623–630
  18. Shikora SA, Bistrian BR, Borlase BC, Blackburn GL, Stone MD, Benotti PN. Work of breathing: reliable predictor of weaning and extubation. Crit Care Med. 1990;18:157–162
  19. Oh TE, Bhatt S, Lin ES, Hutchinson RC, Low JM. Plasma catecholamines and oxygen consumption during weaning from mechanical ventilation. Intensive Care Med. 1991;17:199–203
  20. Meyer R, Briassouli E, Briassoulis G, Habibi P. Evaluation of the M-COVX metabolic monitor in mechanically ventilated adult patients. e-SPEN Eur J Clin Nutr Metab. 2008;3:e232–e239
  21. Stuart-Andrews CR, Peyton P, Robinson GJ, Terry D, O'Connor B, Van der Herten C, et al. In vivo validation of the M-COVX metabolic monitor in patients under anaesthesia. Anaesth Intensive Care. 2007;35:398–405
  22. Brandi LS, Bertolini R, Santini L, Cavani S. Effects of ventilator resetting on indirect calorimetry measurement in the critically ill surgical patient. Crit Care Med. 1999;27:531–539
  23. Petros S, Engelmann L. Validity of an abbreviated indirect calorimetry protocol for measurement of resting energy expenditure in mechanically ventilated and spontaneously breathing critically ill patients. Intensive Care Med. 2001;27:1164–1168
  24. Rose L, Hawkins M. Airway pressure release ventilation and biphasic positive airway pressure: a systematic review of definitional criteria. Intensive Care Med. 2008;34:1766–1773
  25. Kazmaier S, Rathgeber J, Buhre W, Buscher H, Busch T, Mensching K, et al. Comparison of ventilatory and haemodynamic effects of BIPAP and S-IMV/PSV for postoperative short-term ventilation in patients after coronary artery bypass grafting. Eur J Anaesthesiol. 2000;17:601–610
  26. Luehrs P. McKilvain K. Frazier Z. APRV using the bivent mode on the Servo i ventilator. www.rcjournal.com/abstracts/2004.
  27. Weyland W, Schuhmann M, Rathgeber J, Weyland A, Fritz U, Laier-Groeneveld G, et al. Oxygen cost of breathing for assisted spontaneous breathing modes: investigation into three states of pulmonary function. Intensive Care Med. 1995;21:211–217
  28. Barle H, Söderberg P, Haegerstrand C, Markström A. Bi-level positive airway pressure ventilation reduces the oxygen cost of breathing in long-standing post-polio patients on invasive home mechanical ventilation. Acta Anaesthesiol Scand. 2005;49:197–202
  29. Staudinger T, Kordova H, Röggla M, Tesinsky P, Locker GJ, Laczika K, et al. Comparison of oxygen cost of breathing with pressure-support ventilation and biphasic intermittent positive airway pressure ventilation. Crit Care Med. 1998;26:1518–1522
  30. Lessard MR, Guérot E, Lorino H, Lemaire F, Brochard L. Effects of pressure-controlled with different I: E ratios versus volume-controlled ventilation on respiratory mechanics, gas exchange, and hemodynamics in patients with adult respiratory distress syndrome. Anesthesiology. 1994;80:983–991
  31. Gregoretti C, Olivieri C, Navalesi P. Physiologic comparison between conventional mechanical ventilation and transtracheal open ventilation in acute traumatic quadriplegic patients. Crit Care Med. 2005;33:1114–1118
  32. Cabello B, Thille AW, Drouot X, Galia F, Mancebo J. d'Ortho MP, Brochard L. Sleep quality in mechanically ventilated patients: comparison of three ventilatory modes. Crit Care Med. 2008;36:1749–1755
  33. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–310

PII: S0899-9007(09)00123-3

doi: 10.1016/j.nut.2009.01.018

Nutrition
Volume 25, Issue 11 , Pages 1106-1114 , November 2009